cover image: S-35 REPLACEMENT OF PRIVATE DRAIN CONNECTIONS TABLE OF CONTENTS

Premium

20.500.12592/xj6k00

S-35 REPLACEMENT OF PRIVATE DRAIN CONNECTIONS TABLE OF CONTENTS

25 Jul 2022

The private drain connection, from the 150mm cleanout at property line, to the dwelling may be either a 150mm diameter pipe or 100mm diameter pipe with positive grade from the cleanout to the interior of the dwelling, extending a maximum of 0.91m into the dwelling. [...] The City Engineer reserves the right to consider other methods but in all cases a sound and watertight joint must be achieved and the City Engineer will be the sole judge in determining the acceptability of the alternate method(s). [...] The contractor shall open the pavement or driveway over the mainline municipal sewer as required to make the tap or connection to the existing sewer, and restoration shall be in accordance with City of Windsor Specification S-29 and Standard Drawing AS-207A, B and C for road openings or as directed by the City Engineer for driveways. [...] 35.11 CCTV INSPECTION OF PRIVATE SEWER The contractor must have equipment available to CCTV inspect and record the inside condition of the private drain connections as well as the underground plumbing of the home by means of a TV monitor and provide a digital copy of the video to the City for review. [...] The contractor shall submit to the City Engineer after the completion of the project, a statement showing the value of the work executed.